Carbon Monoxide Safety: What Advanced Combustion Analysis Can Reveal

Older furnaces and natural-draft rental water heaters deserve a careful look at combustion, draft and venting. Here’s what a professional analyzer measures, what it cannot replace, and the steps to take if a CO alarm sounds.

Published November 21, 2026 · 8 min read · Heat and Cool Brothers Inc.

Combustion analyzer probe animationA schematic professional analyzer takes a flue-gas sample through a probe at a furnace vent test port. No real diagnostic values are shown.COMBUSTION CHECK · SCHEMATICO₂CO— —— —PROFESSIONAL ANALYZEROLDER FURNACEFLUE TEST PORTProbe samples flue gas. A qualified technician interprets results for the appliance.
Schematic animation only — the screen intentionally shows no readings. Analyzer results must be interpreted by a qualified technician against the appliance instructions and applicable requirements.

First, a critical distinction: CO is not CO₂

Carbon monoxide (CO) is a poisonous gas produced by incomplete fuel combustion. You cannot see, smell or taste it. Carbon dioxide (CO₂) is a different gas. A combustion analyzer may report or calculate CO₂ as one indicator of combustion performance, but it is carbon monoxide (CO) that creates the acute poisoning risk discussed in this guide.

Neither an analyzer’s calculated combustion number nor a service visit replaces a certified carbon-monoxide alarm inside the home. CO alarms warn occupants; a technician’s analyzer helps investigate how a fuel-burning appliance is operating.

Possible exposure symptoms include headache, tiredness, dizziness, nausea, shortness of breath or difficulty thinking. Symptoms can resemble the flu. If anyone feels unwell and CO is possible, move everyone outside to fresh air and call 911 or emergency services—do not stay inside to troubleshoot.

Why an older furnace deserves a careful combustion and venting check

Age alone does not prove a furnace is unsafe, and a newer appliance can also fail. But years of heating cycles, corrosion, prior repairs, restricted airflow or a damaged vent can change how a furnace burns fuel and sends exhaust outdoors. A proper inspection considers the whole appliance and its installation—not just whether it starts.

A qualified technician may inspect the heat exchanger and burner area, confirm the vent path and combustion-air supply, check operating conditions, and use a calibrated analyzer where the manufacturer’s procedure calls for it. An isolated reading is not a complete diagnosis. Results have to be interpreted alongside the appliance design, fuel, operating state and applicable instructions.

If a furnace is repeatedly shutting down, producing visible soot, showing corrosion around the vent, or associated with a CO alarm, stop troubleshooting and arrange professional help. If the alarm sounds, leave first and call emergency services from outside.

Natural-draft rental water heaters: what tenants should know

A natural-draft water heater is not automatically unsafe because it is old or rented. It relies on buoyancy and a clear, correctly installed vent to carry combustion products outside, and it draws combustion air from the room. Vent problems, inadequate air supply, competing exhaust fans, or changes to the building can affect draft and cause combustion products to spill into the space.

In a rental home, do not adjust the burner, disconnect the vent, or open appliance panels. If you notice soot, a loose or damaged vent, repeated pilot outages, unusual condensation near the vent, or a CO alarm, get people to fresh air and follow the emergency steps above. For non-emergency concerns, contact the landlord or rental provider in writing and request assessment by a qualified fuel-safety professional. Keep your own certified CO alarms installed and working.

For replacement or service options, see our hot-water tank service page, water-heater and tankless overview, and water-heater rental changeover guide.

What an advanced combustion analyzer measures

Professional analyzers combine sensors with temperature and pressure measurements. Depending on the instrument and test setup, a technician may record:

  • Oxygen (O₂) in flue gas, which helps assess the air-fuel relationship.
  • Carbon monoxide (CO) in flue gas, interpreted with the appliance operating at the conditions required by its test procedure.
  • Flue-gas temperature, used with other measurements to assess heat transfer and venting conditions.
  • Draft or pressure, which helps evaluate whether the vent is moving combustion products as intended.
  • Calculated values such as excess air, carbon dioxide (CO₂) estimate or combustion efficiency, depending on the analyzer, selected fuel and configuration.
  • Ambient CO from a separate room-air test when appropriate. A flue-gas reading and a room-air reading answer different questions.

The probe is placed at the correct sampling location, the analyzer is allowed to stabilize as directed, and the technician records the operating state and relevant readings. These measurements support diagnosis; they do not, by themselves, certify that a home is free of CO.

What combustion analysis can—and cannot—tell you

Combustion testing can help identify an abnormal combustion pattern, draft concern or operating condition that warrants further investigation. It can support service decisions such as cleaning, adjustment, repair, vent correction or replacement after the cause is confirmed.

It is not a substitute for a home CO alarm, a complete furnace inspection, a venting assessment or the appliance manufacturer’s safety procedure. One “good” reading at one moment cannot rule out every intermittent fault or building-pressure problem. Ask the technician what was measured, under what conditions, what the result means for this exact appliance, and what corrective action—if any—is recommended.

For furnace maintenance and repair, start with furnace and heating service or read our safe no-heat troubleshooting guide. Do not open the furnace or try to reproduce a suspected venting problem yourself.

CO alarms and Ontario homes

Ontario’s updated Fire Code requirements that took effect January 1, 2026 call for CO alarms adjacent to sleeping areas and on every storey in existing homes with a fuel-burning appliance, fireplace or attached garage. Follow the alarm manufacturer’s placement, testing and replacement instructions, and use a model certified for use in Canada.

Test alarms as directed and do not remove batteries to silence nuisance alerts. A chirp can mean a low battery or end of service life; follow the label and manufacturer’s instructions. If the alarm itself sounds, treat it as an emergency and leave.

Trusted safety references

Need a furnace or water-heater assessment?

Heat and Cool Brothers serves homeowners and rental properties in Georgina, Keswick, Newmarket, Bradford, East Gwillimbury, Aurora, Richmond Hill and Markham. We can help arrange an HVAC service visit and explain the findings. If an alarm is sounding or anyone feels unwell, leave and call emergency services first.

Visit the CO-safety resource hub for related guides and local service links.

Call Heat and Cool Brothers: +1 (289) 210-4080 or request an appointment online.

Get in touch

Book online or call for service.

24/7 emergency service or planned work — a real technician answers the phone and arrives prepared.

Call nowBook online